| Conditions Contributing to Underground Copper Corrosion |
|
|
|
Copper is a noble metal that occurs naturally in its elemental form, and it is almost totally impervious to corrosion from soils found worldwide. But it would be misleading to infer that copper will not corrode. Here is identified that copper pipe or tubing may be subject to external corrosion. These situations are discussed in detail, and suggestions are given on how to identify underground corrosion of copper pipe without excavating and how to mitigate existing corrosion conditions. In beliefly by knowledgeable engineers, architects, and water utility personnel that, copper is not adversely affected by the majority of soils worldwide is well founded. Uncommonly well-preserved copper artifacts continue to be recovered in Mesopotamia from beneath the clay deposited by the "Great Flood," which is believed to have occurred about 4000 B.C.(1) Many of the underground copper pipes used to convey water in Egypt nearly 5000 years ago are still in existence. Furthermore, copper is one of the few metals that exists as an element in its natural form. There is also the outstanding history of copper tubing as a highly corrosion-resistant material in most underground environments. There are conditions, however, that can cause copper to corrode when it is exposed to certain soils. These include
Abnormally Aggressive Soils Three definitive studies on the underground corrosion of copper have been conducted.(2,3,4) Very likely, this apparent lack of interest in the soil-side corrosion of copper is the result of the metal's known corrosion resistance in underground environments. Analysis of the results obtained in these three independent investigations clearly establishes that the underground corrosion of copper is unusually complicated. In general, corrosion cannot be directly related to any one or even several factors, as many interrelated soil conditions are involved. The data presented in the three studies and the results of others (5,6) permit some tentative conclusions regarding the corrosion of copper in underground environments. These include
Soils containing appreciable amounts of ammonia compounds are usually corrosive to copper. The appearance of the copper surface and identification of the corrosion products generally provide insight regarding the cause of deterioration. For example, green copper corrosion products are often basic copper carbonate, basic copper sulfate, or copper oxychlorides. The existence of appreciable amounts of copper oxychlorides in the corrosion products would be expected for a copper water tube that had been buried in a low-resistivity tidal marsh environment. A heavy black layer on the copper would suggest the presence of copper sulfide and the possibility of anaerobic bacteria activity as the cause of corrosion. The presence of ammonia, in combination with sulfate compounds on the copper surface, indicates that the cause of corrosion could be lawn fertilizer. Corrosion of underground copper can be either uniform or localized (Fig-1). ![]() Localized corrosion suggests the existence of local-action cells such as those created by nonhomogeneous backfills. Local-action-cell corrosion is also suspected when the underside of a horizontal copper-water-tube service line suffers preferential corrosion. Concentration-Cell Corrosion This is commonly referred to as an oxygen-differential concentration cell. Oxygen-type concentration-cell corrosion is often the explanation for the preferential underside corrosion of a copper water tube. The underside of the tube is often in contact with reduced oxygen-content, undisturbed soil, whereas the upper portion of the tube is exposed to aerated backfill. Corrosion on the underside of the tube is aggravated under this condition by the large ratio of cathode area to anode area that exists. Oxygen-differential concentration cells can also be created by nonhomogeneous backfills. Metals and alloys in contact with lumps of clay will almost always be anodic to nearby metal when the major backfill material is sandy loam. Similarly, long-line corrosion currents can exist if the service line passes through areas of major soil differences. Corrosion of underground copper can be caused by certain neutral-salt concentration cells. Regions of elevated chloride are generally anodic to regions of reduced chloride. Such choride-type concentration cells are sometimes created by deicing salts, such as in a serviceline trench that can act as a subsurface drainage ditch for several years following its excavation and backfill. There is also reason to believe that regions on a metal surface in contact with soil having a low ph will be cathodic to areas on the same metal where the localized pH is somewhat higher. The concept of hydrogen-ion concentration cells is supported in part by the observation that the corrosion potential of a metal or alloy generally becomes increasingly positive as the pH of the environment decreases. (7) Stray Direct Current Corrosion A common source of stray DC electricity is an impressed-current-type cathodic protection system such as those widely used by utilities and gas and oil transmission companies for the mitigation of corrosion on underground steel pipelines. Electric utility high-voltage direct-current (HVDC) transmission systems, DC-powered transit systems, welding facilities, and mining equipment are also potential sources of stray direct current. Faulty Design and Workmanship It is also known that improperly prepared or installed flared tube joints on underground service lines, caused by the presence of residual burrs on the seating surface, can result in localized erosion and corrosion. When this occurs, the problem is readily recognized by the U-shaped pits on the affected areas, which are essentially free of residual corrosion products (Fig-2). This can be aggravated by abnormally fast water velocities in the distribution system. Alternating Current Action Some investigators believe that a critical AC density must be exceeded for AC corrosion to occur.(12,13) It is also possible that AC facilitates depolarization of the local anodes and cathodes on an underground copper surface.(11) This depolarization would be expected to increase the corrosion-current density and the resultant corrosion rate. Until these differences of opinion are reconciled and recent research results are corroborated, it is reasonable to believe that the commonly used practice of grounding electrical systems to underground copper water systems can lead to corrosion. If the copper plumbing system is connected to a nonconducting main, such as asbestos-cement, some corrosion damage can be anticipated where the current leaves the copper, even if the current is alternating. Further, cuprous oxide could become semiconducting under certain conditions of soil pH and electrical-field intensity. Grounding of the AC system to the underground copper water tubing and unbalance in the AC system could very well be involved in the underground corrosion process. Thermogalvanic Effects Thermal effects in the immediate vicinity of underground hot-water tubes can sometimes aggravate the corrosion problem by concentrating salts at these locations through the evaporation of water that might be draining through the soil. Galvanic action Copper is anodic to carbon, and corrosion can be expected to occur if the cinders used for backfill contain appreciable amounts of carbon. Moisture, however, must be present for this galvanic action to take place. It is also known that copper embedded in concrete will normally be cathodic to nearby copper that is exposed to soil. This subtle form of galvanic corrosion can cause the deterioration of copper exposed to the soil in the immediate vicinity of the soil-concrete interface. Reportedly, this form of corrosion is the reason that complete concrete encasement of copper water tubes is required in some Southern California areas.(5) Chart 1. Tentative correlation between tube-to-soil potential and the underground corrosion activity of copper(17)
In general, negative potentials will be recorded where the stray current enters the copper tube and the material is cathodically protected. Much less negative and even positive potentials will be obtained where the stray current leaves the underground structure, returns to the earth, and causes corrosion. Stray-current corrosion can also be confirmed with the tube-to-soil potential survey technique. Interruption of the offending current source will often reveal major potential differences between the current-off and current-on readings, especially if the reference cell is located at the site of major anodic activity. Mitigating the Underground Corrosion of Copper
One of the most cost-effective methods for mitigating the corrosion of copper exposed to a hostile environment is cathodic protection. (17,19) Corrosion control is achieved when the potentials of the cathodes on the corroding copper surface are polarized to the open-circuit potentials of the local-action anodes. For most copper-water-tube systems, this can be readily accomplished using sacrificial anodes. Zinc anodes in packaged backfills can be used, provided the soil resistivity is less than approximately 2000 ohm-cm. Packaged magnesium anodes should be used if the soil resistivity is greater than about 2000 ohm-cm. Although the current required to protect underground copper cathodically will vary depending on local soil conditions, copper apparently polarizes quite readily in most soils. The current required to protect a square foot of bare copper can be as low as 0.4-1.7 mA.(20) The belief that relatively small currents are required to protect underground copper cathodically is supported by the observation that this form of electrochemical corrosion control is generally achieved automatically when service lines are in metallic contact with cast iron water mains. General guidelines for the design of a workable cathodic protection system for underground copper are available in the technical literature. Improvements in the drainage pattern, so that water flows away from the building or service line, can be used to eliminate underground copper corrosion problems. The trench containing the service line must not be directly downstream of any septic drainage systems or building downspouts. Similarly, the trench must not be a collection basin for deicing salts and lawn fertilizer. For those areas in which it is known that the underground copper will be exposed to abnormally aggressive soils, it is possible to encase the metal completely in a selective backfill. These backfills can be prepared by mixing sand with cement powder, screened soil with chalk, or screened soil with pulverized limestone. A selective backfill, however, may not accomplish its intended objective if the drainage is such that aggressive species can concentrate and come into contact with copper. Stray-current corrosion of underground copper should be mitigated by the responsible organization. This deleterious form of underground corrosion is readily rendered innocuous through resistance bonds and the proper installation of sacrificial anodes on the adversely affected structure. For severe conditions, when the offending current source is an impressed-current-type cathodic protection system, it is sometimes necessary to relocate the anode bed associated with the cause of the interference. It cannot be overemphasized that underground copper-water-tube systems must be properly designed and installed. Provisions must be made for thermal expansion where copper hot-water tubing passes through concrete slabs. Improperly installed flared tube joints on copper service lines must be avoided. [From- J.R. Myers, JRM Associates, 4198 Merlyn Drive, Franklin, OH 45005; A. Cohen, Copper Development Association Inc., 260 Madison Ave., New York, NY 10016] References
|